Diff of /arm/README.md [000000] .. [20044c]

Switch to side-by-side view

--- a
+++ b/arm/README.md
@@ -0,0 +1,31 @@
+# MyoArm 0.1
+
+## General:
+
+The myoArm mujoco musculoskeletal (MSK) model is generated from: MoBL - human upper
+extremity model [https://simtk.org/projects/upexdyn/] from Opensim and the MyoHand model [https://github.com/MyoHub/myo_sim/tree/main/hand].
+
+This generated mujoco MSK model has almost identical kinematics, and very similar muscle kinematics (moment arms) and kinetic (forces) properties.
+
+
+## Conversion process:
+
+The myoHand model was generated using our developed automatic conversion pipeline (released on June 2023).
+
+Three Conversion steps were taken to generate the myoLeg models from the reference Osim model:
+
+1. Basic element conversion [bone meshes, joint definitions, muscle paths, wrapping objects]
+2. Moment arm optimization [matching the moment arm of each muscle by optimizing how muscles wrap over wrapping objects]
+3. Muscle force optimizaiton [matching the muscle force-length relationship by optimizing muscle parameters]
+
+After the conversion, a manual adjusting process is done to correct the abnormal results.
+
+## Maunal adjustment:
+- Adjustments post conversion to optimize for kinematic and dynamic behaviors
+
+## Contact Geometries:
+- Manually designed with references
+- Contact properties optimized for contact rich behaviors
+
+## Issues:
+- N/A