Switch to unified view

a b/sub-pavia03/anat/sub-pavia03_T1w.json
1
{
2
    "Modality": "MR",
3
    "MagneticFieldStrength": 3,
4
    "ImagingFrequency": 123.228,
5
    "Manufacturer": "Siemens",
6
    "ManufacturersModelName": "Skyra",
7
    "InstitutionName": "Istituto_Neurologico_Mondino",
8
    "InstitutionalDepartmentName": "Department",
9
    "InstitutionAddress": "Via_Mondino_2_Pavia_District_IT_27100",
10
    "DeviceSerialNumber": "45358",
11
    "StationName": "AWP45358",
12
    "BodyPartExamined": "HEADNECK",
13
    "PatientPosition": "HFS",
14
    "ProcedureStepDescription": "R.M._DEL_CERVELLO_E_DEL_TRONCO_ENCEFALICO_-_3T",
15
    "SoftwareVersions": "syngo_MR_D13C",
16
    "MRAcquisitionType": "3D",
17
    "SeriesDescription": "T1w",
18
    "ProtocolName": "T1w",
19
    "ScanningSequence": "GR_IR",
20
    "SequenceVariant": "SK_SP_MP",
21
    "ScanOptions": "IR",
22
    "SequenceName": "_tfl3d1_16",
23
    "ImageType": [
24
        "ORIGINAL",
25
        "PRIMARY",
26
        "M",
27
        "NORM",
28
        "DIS3D",
29
        "DIS2D"
30
    ],
31
    "SeriesNumber": 2,
32
    "AcquisitionTime": "18:58:17.737500",
33
    "AcquisitionNumber": 1,
34
    "SliceThickness": 1,
35
    "SAR": 0.0916667,
36
    "EchoTime": 0.00372,
37
    "RepetitionTime": 2,
38
    "InversionTime": 1,
39
    "FlipAngle": 9,
40
    "PartialFourier": 1,
41
    "BaseResolution": 320,
42
    "ShimSetting": [
43
        6776,
44
        -672,
45
        7413,
46
        252,
47
        90,
48
        -254,
49
        726,
50
        -167
51
    ],
52
    "TxRefAmp": 388.197,
53
    "PhaseResolution": 1,
54
    "ReceiveCoilName": "Spine_32",
55
    "ReceiveCoilActiveElements": "HE1-4;NE1,2;SP1,2",
56
    "CoilString": "HE1-4;NE1_2;SP1_2",
57
    "PulseSequenceDetails": "%SiemensSeq%_tfl",
58
    "ConsistencyInfo": "N4_VD13C_LATEST_20121124",
59
    "PercentPhaseFOV": 81.25,
60
    "PhaseEncodingSteps": 259,
61
    "AcquisitionMatrixPE": 260,
62
    "ReconMatrixPE": 320,
63
    "PixelBandwidth": 150,
64
    "DwellTime": 1.04e-05,
65
    "ImageOrientationPatientDICOM": [
66
        1.21997e-05,
67
        1,
68
        -0.000348855,
69
        0.0348995,
70
        -0.000349068,
71
        -0.999391
72
    ],
73
    "InPlanePhaseEncodingDirectionDICOM": "ROW",
74
    "ConversionSoftware": "dcm2niix",
75
    "ConversionSoftwareVersion": "v1.0.20181125  GCC4.8.2",
76
    "Dcm2bidsVersion": "2.1.4",
77
    "SpatialReference": {
78
        "Resampling": "0.8x0.8x0.8",
79
        "Reorientation": "RPI"
80
    }
81
}