Switch to unified view

a b/sub-pavia01/anat/sub-pavia01_T2w.json
1
{
2
    "Modality": "MR",
3
    "MagneticFieldStrength": 3,
4
    "ImagingFrequency": 123.228,
5
    "Manufacturer": "Siemens",
6
    "ManufacturersModelName": "Skyra",
7
    "InstitutionName": "Istituto_Neurologico_Mondino",
8
    "InstitutionalDepartmentName": "Department",
9
    "InstitutionAddress": "Via_Mondino_2_Pavia_District_IT_27100",
10
    "DeviceSerialNumber": "45358",
11
    "StationName": "AWP45358",
12
    "BodyPartExamined": "HEAD",
13
    "PatientPosition": "HFS",
14
    "ProcedureStepDescription": "R.M._DEL_CERVELLO_E_DEL_TRONCO_ENCEFALICO_-_3T",
15
    "SoftwareVersions": "syngo_MR_D13C",
16
    "MRAcquisitionType": "3D",
17
    "SeriesDescription": "T2w",
18
    "ProtocolName": "T2w",
19
    "ScanningSequence": "SE",
20
    "SequenceVariant": "SK_SP_OSP",
21
    "ScanOptions": "PFP",
22
    "SequenceName": "_spcR_100",
23
    "ImageType": [
24
        "ORIGINAL",
25
        "PRIMARY",
26
        "M",
27
        "NORM",
28
        "DIS3D",
29
        "DIS2D"
30
    ],
31
    "SeriesNumber": 3,
32
    "AcquisitionTime": "15:40:16.137500",
33
    "AcquisitionNumber": 1,
34
    "SliceThickness": 0.8,
35
    "SAR": 0.68723,
36
    "EchoTime": 0.122,
37
    "RepetitionTime": 1.5,
38
    "FlipAngle": 120,
39
    "PartialFourier": 1,
40
    "BaseResolution": 320,
41
    "ShimSetting": [
42
        6818,
43
        -908,
44
        7129,
45
        -32,
46
        88,
47
        -505,
48
        1979,
49
        -173
50
    ],
51
    "TxRefAmp": 382.374,
52
    "PhaseResolution": 1,
53
    "PhaseOversampling": 0.8,
54
    "ReceiveCoilName": "Spine_32",
55
    "ReceiveCoilActiveElements": "HE3,4;NE1,2;SP1",
56
    "CoilString": "HE3_4;NE1_2;SP1",
57
    "PulseSequenceDetails": "%SiemensSeq%_tse_vfl",
58
    "ConsistencyInfo": "N4_VD13C_LATEST_20121124",
59
    "PercentPhaseFOV": 100,
60
    "EchoTrainLength": 77,
61
    "PhaseEncodingSteps": 431,
62
    "AcquisitionMatrixPE": 320,
63
    "ReconMatrixPE": 320,
64
    "PixelBandwidth": 625,
65
    "DwellTime": 2.5e-06,
66
    "ImageOrientationPatientDICOM": [
67
        0,
68
        1,
69
        -2.05103e-10,
70
        0,
71
        -2.05103e-10,
72
        -1
73
    ],
74
    "InPlanePhaseEncodingDirectionDICOM": "COL",
75
    "ConversionSoftware": "dcm2niix",
76
    "ConversionSoftwareVersion": "v1.0.20181125  GCC4.8.2",
77
    "Dcm2bidsVersion": "2.1.4",
78
    "SpatialReference": {
79
        "Resampling": "0.8x0.8x0.8",
80
        "Reorientation": "RPI"
81
    }
82
}