Diff of /README.md [000000] .. [a68ae8]

Switch to unified view

a b/README.md
1
## Two-tiered response of cardiorespiratory-cerebrovascular networks to orthostatic challenge
2
Andras Eke, Peter Mukli, Orestis Stylianou, Andras Hartmann 
3
4
Published: May 17, 2021. Version: 1.0
5
---
6
7
<div class="col-md-8">
8
        
9
          <div class="alert alert-secondary">
10
11
  
12
    
13
      <p>
14
        <strong>When using this resource, please cite: </strong>
15
        <a href="#citationModal" data-toggle="modal">(show more options)</a>
16
        <br><span>Eke, A., Mukli, P., Stylianou, O., &amp; Hartmann, A. (2021). Two-tiered response of cardiorespiratory-cerebrovascular networks to orthostatic challenge (version 1.0). <i>PhysioNet</i>. <a href="https://doi.org/10.13026/73w7-x881">https://doi.org/10.13026/73w7-x881</a>.</span>
17
      </p>
18
19
      <div class="modal fade" id="citationModal">
20
  <div class="modal-dialog citation" role="document">
21
    <div class="modal-content">
22
      <div class="modal-header">
23
        <h5 class="modal-title">Cite</h5>
24
        <button type="button" class="close" data-dismiss="modal" aria-label="Close">
25
          <span aria-hidden="true">×</span>
26
        </button>
27
      </div>
28
      <div class="modal-body">
29
30
      <table><tbody>
31
        
32
          <tr>
33
            <th>MLA</th>
34
            <td>Eke, Andras, et al. "Two-tiered response of cardiorespiratory-cerebrovascular networks to orthostatic challenge" (version 1.0). <i>PhysioNet</i> (2021), <a href="https://doi.org/10.13026/73w7-x881">https://doi.org/10.13026/73w7-x881</a>.</td>
35
          </tr>
36
        
37
          <tr>
38
            <th>APA</th>
39
            <td>Eke, A., Mukli, P., Stylianou, O., &amp; Hartmann, A. (2021). Two-tiered response of cardiorespiratory-cerebrovascular networks to orthostatic challenge (version 1.0). <i>PhysioNet</i>. <a href="https://doi.org/10.13026/73w7-x881">https://doi.org/10.13026/73w7-x881</a>.</td>
40
          </tr>
41
        
42
          <tr>
43
            <th>Chicago</th>
44
            <td>Eke, Andras, Mukli, Peter, Stylianou, Orestis, and Andras Hartmann. "Two-tiered response of cardiorespiratory-cerebrovascular networks to orthostatic challenge" (version 1.0). <i>PhysioNet</i> (2021). <a href="https://doi.org/10.13026/73w7-x881">https://doi.org/10.13026/73w7-x881</a>.</td>
45
          </tr>
46
        
47
          <tr>
48
            <th>Harvard</th>
49
            <td>Eke, A., Mukli, P., Stylianou, O., and Hartmann, A. (2021) 'Two-tiered response of cardiorespiratory-cerebrovascular networks to orthostatic challenge' (version 1.0), <i>PhysioNet</i>. Available at: <a href="https://doi.org/10.13026/73w7-x881">https://doi.org/10.13026/73w7-x881</a>.</td>
50
          </tr>
51
        
52
          <tr>
53
            <th>Vancouver</th>
54
            <td>Eke A, Mukli P, Stylianou O, Hartmann A. Two-tiered response of cardiorespiratory-cerebrovascular networks to orthostatic challenge (version 1.0). PhysioNet. 2021. Available from: <a href="https://doi.org/10.13026/73w7-x881">https://doi.org/10.13026/73w7-x881</a>.</td>
55
          </tr>
56
        
57
      </tbody></table>
58
            </div>
59
      <div class="modal-footer">
60
        <button type="button" class="btn btn-secondary" data-dismiss="modal">Close</button>
61
      </div>
62
    </div>
63
  </div>
64
</div>
65
66
    
67
68
    
69
  
70
    
71
      <p>
72
        <strong>Please include the standard citation for PhysioNet:</strong>
73
        <a href="#citationModalPlatform" data-toggle="modal">(show more options)</a>
74
          <br><span>Goldberger, A., Amaral, L., Glass, L., Hausdorff, J., Ivanov, P. C., Mark, R., ... &amp; Stanley, H. E. (2000). PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation [Online]. 101 (23), pp. e215–e220.</span>
75
      </p>
76
    
77
78
  <div class="modal fade" id="citationModalPlatform">
79
  <div class="modal-dialog citation" role="document">
80
    <div class="modal-content">
81
      <div class="modal-header">
82
        <h5 class="modal-title">Cite</h5>
83
        <button type="button" class="close" data-dismiss="modal" aria-label="Close">
84
          <span aria-hidden="true">×</span>
85
        </button>
86
      </div>
87
      <div class="modal-body">
88
89
  <table><tbody>
90
    
91
        
92
          <tr>
93
            <th>APA</th>
94
            <td>Goldberger, A., Amaral, L., Glass, L., Hausdorff, J., Ivanov, P. C., Mark, R., ... &amp; Stanley, H. E. (2000). PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation [Online]. 101 (23), pp. e215–e220.</td>
95
          </tr>
96
        
97
    
98
        
99
          <tr>
100
            <th>MLA</th>
101
            <td>Goldberger, A., et al. "PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation [Online]. 101 (23), pp. e215–e220." (2000).</td>
102
          </tr>
103
        
104
    
105
        
106
          <tr>
107
            <th>CHICAGO</th>
108
            <td>Goldberger, A., L. Amaral, L. Glass, J. Hausdorff, P. C. Ivanov, R. Mark, J. E. Mietus, G. B. Moody, C. K. Peng, and H. E. Stanley. "PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation [Online]. 101 (23), pp. e215–e220." (2000).</td>
109
          </tr>
110
        
111
    
112
        
113
          <tr>
114
            <th>HARVARD</th>
115
            <td>Goldberger, A., Amaral, L., Glass, L., Hausdorff, J., Ivanov, P.C., Mark, R., Mietus, J.E., Moody, G.B., Peng, C.K. and Stanley, H.E., 2000. PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation [Online]. 101 (23), pp. e215–e220.</td>
116
          </tr>
117
        
118
    
119
        
120
          <tr>
121
            <th>VANCOUVER</th>
122
            <td>Goldberger A, Amaral L, Glass L, Hausdorff J, Ivanov PC, Mark R, Mietus JE, Moody GB, Peng CK, Stanley HE. PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation [Online]. 101 (23), pp. e215–e220.</td>
123
          </tr>
124
        
125
    
126
  </tbody></table>
127
        </div>
128
      <div class="modal-footer">
129
        <button type="button" class="btn btn-secondary" data-dismiss="modal">Close</button>
130
      </div>
131
    </div>
132
  </div>
133
</div>
134
135
136
</div>
137
        
138
139
        
140
          
141
          
142
            <h2 id="abstract">Abstract</h2>
143
<p><span><span>The authors used this dataset&nbsp;to evaluate the responsiveness of the cardiorespiratory-cerebrovascular networks by capturing linear and nonlinear interdependencies to postural changes. Ten young healthy adults participated in our study between December 2009 and February 2010 at Semmelweis University, Faculty of Medicine. Non-invasive measurements of arterial blood pressure (ABP), cardiac cycle duration&nbsp;(derived from ABP signals), breath-to-breath interval (capnography), cerebral blood flow velocity (BFV, recorded by transcranial Doppler sonography), and cerebral hemodynamics (hemoglobin signals monitored by near-infrared spectroscopy) were performed for 30-minutes in resting state, followed by a one-minute stand-up and a one-minute sit-down period. BFV and ABP signals were calibrated, and the&nbsp;dataset contains values in cm/s and mmHg, respectively. NIRS measurement yielded intensity values (raw signals) from which change of HbO (oxyhemoglobin), HbR (deoxyhemoglobin) and HbT (total hemoglobin) concentration in tissue can be calculated (in micromol/liter). Raw NIRS signals were synchronized to BFV, ABP and capnography time series yielding 33 minutes of resampled data (sampling frequency: ~ 3 Hz).</span></span></p>
144
<hr>
145
146
<h2 id="background">Background</h2>
147
<p><span><span><span>Dynamic interdependencies within and between physiological systems and subsystems are essential for the organism to maintain its steady-state via a plethora of homeostatic mechanisms [1]. The aim of physiological regulation&nbsp;is to restore the optimal state of the internal environment that is challenged&nbsp;by continuous perturbations. The deviation of actual value from its physiological set point elicits multiple negative feedback loops that occur at various time scales&nbsp;resulting in a delayed response with an amplitude proportional to perturbation [2-4].&nbsp;The recently introduced concept of Network Physiology offers a novel framework for an enhanced characterization, quantification, and understanding of the dynamical interactions between organ systems underlying homeostatic adaptation [5-7].</span></span></span></p>
148
149
<p><span><span><span>These interactions mediate regulatory responses elicited by various perturbations, such as the high-pressure baroreflex and cerebral autoregulation, alleviating the impact of orthostatic stress on cerebral hemodynamics and oxygenation [8]</span></span></span>. Under physiological conditions, h<span><span><span>igh-pressure baroreflex helps to adapt to orthostatic stress - a consequence of&nbsp;</span></span></span>an abrupt change in body position promptly altering the central arterial blood pressure (ABP) - while cerebral blood flow&nbsp;is maintained by&nbsp;autoregulatory mechanisms within a range of ABP values. <span><span><span>&nbsp;The dataset was collected as part of a&nbsp;study to evaluate the responsiveness of the cardiorespiratory-cerebrovascular networks by capturing linear and nonlinear interdependencies to postural changes. </span></span></span></p>
150
<hr>
151
152
<h2 id="methods">Methods</h2>
153
<p><span><span>A total of 10 healthy young adults - students and employees of Semmelweis University -&nbsp;were recruited for participation in this study (age: 26.3±3.7 years, 5-5 female and male). None of them reported neurological, psychiatric or cardiovascular diseases or living with the condition of orthostatic hypotension. One male subject was excluded due to a lack of acoustic window necessary for transcranial Doppler (TCD) measurements (see below). Written informed consent was obtained from all subjects prior to participation.<span>&nbsp;</span></span></span></p>
154
155
<p><span><span>The measurement protocol consisted of a 30-minutes resting-state period followed by a one-minute stand-up and one-minute sit-down period. Subjects were asked to change body position abruptly. The protocol was approved by </span></span>Regional and Institutional Committee&nbsp;of Science and Research Ethics (ethical approval number 53/2009)<em>.&nbsp;</em></p>
156
157
<p>Arterial blood pressure was recorded non-invasively by using tonometric monitors (Colin BP-508, Colin Medical Technology, Corporation, Komaki City, Japan). The array of transducers - embedded in a wristband adjusted to the participant - captured signals from the right radial artery over the styloid process. Capnographic measurements were carried out with the same device.&nbsp;Blood flow velocities were recorded bilaterally&nbsp;in the middle cerebral arteries with the aid of 2 MHz transducers in pulsed-wave mode (DWL Multidop-T, Sipplingen, Germany). Transducers&nbsp;fitted in a probe holder mounted on the head of the participant&nbsp;that ensured their&nbsp;position during measurement. Signals were digitized at a 100 Hz sampling rate with DT9816 data acquisition device (Data Translations, Marlborough,&nbsp;Massachusetts, United States) and were captured by Winview LE software (Team Solutions Inc., Grande Vista Ave Laguna Niguel, California, United States).&nbsp;</p>
158
159
<p><span><span><span>The consecutive values of cardiac cycle durations (an estimate of&nbsp;RR-interval) were&nbsp;extracted from blood pressures using the algorithm described in [9-10]. From the respiratory record, we created the breath-to-breath interval time series (BB) were reconstructed from the respiratory signal with the aid of the&nbsp;<em>peakfinder</em>&nbsp;function of MATLAB (version 2012, Mathworks, Natick, MA, USA). All light intensity signals were recorded from 16 regions of the prefrontal cortex at the following wavelengths: 730 nm, 805 nm and 850 nm. </span></span></span><span><span><span>Finally, TCD, CCD, and BB time series&nbsp;were resampled using timestamps corresponding to NIRS signals and markers set during the measurement protocol (resample function of MATLAB). All signals (including BB and RR) were resampled at 3 Hz (interp1 function of MATLAB). The method of resampling was a first-order linear interpolation.</span></span></span></p>
160
<hr>
161
162
<h2 id="description">Data Description</h2>
163
<p>The uploaded data contains the signals resampled with respect to the same sampling time. Data for each subject is stored in a separate file. The CSV files contain all measured data resampled to 3 Hz. Subject 05 was excluded due to an inadequate transtemporal window.</p>
164
165
<ul>
166
    <li>Column 1: TCD signal from a right medial cerebral artery (calibrated)</li>
167
    <li>Column 2: TCD signal from a left medial cerebral artery (calibrated)</li>
168
    <li>Column 3: Arterial blood pressure signal (calibrated)</li>
169
    <li>Column 4: Respiratory signal (uncalibrated)</li>
170
    <li>Column 5-52: Intensity values measured by near-infrared spectroscopy (NIRS) from channel 1-16
171
    <ul>
172
        <li>Columns 5, 8, 11, 14, 17, 20, 23, 26, 29, 32, 35, 38, 41, 44, 47, 50: λ=850 nm</li>
173
        <li>Columns 6, 9, 12, 15, 18, 21, 24, 27, 30, 33, 36, 39, 42, 45, 48, 51: λ=730 nm</li>
174
        <li>Columns 7, 10, 13, 16, 19, 22, 25, 28, 31, 34, 37, 40, 43, 46, 49, 52: λ=805 nm</li>
175
    </ul>
176
    </li>
177
    <li>Column 53: Time stamp</li>
178
</ul>
179
180
<p>Collection of chromofor concentration values started after calibration of NIRS, ~37 seconds (first four markers). Markers were set according to protocol and in case of artefacts.&nbsp;<span><span><span>Regularly we set the following markers: </span></span></span></p>
181
182
<ol>
183
    <li>~1800s – end of resting period, preparing for maneuver</li>
184
    <li>~1860s – participant stands up promptly</li>
185
    <li>~1920s – participant sits down promptly</li>
186
    <li>~1980s – end of sit-down period</li>
187
</ol>
188
189
<p>Further details are provided in the <code>data_info</code> file. Channel layout is displayed in <code>channel_layout.png</code>, reproduced from Figure 1 of Racz et al. [11].</p>
190
<hr>
191
192
<h2 id="usage-notes">Usage Notes</h2>
193
<p>Data are published as CSV files which can be directly imported into common data analysis software. The data is not preprocessed therefore it is necessary to remove motion artefacts. To eliminate these from&nbsp;NIRS signals, we recommend a wavelet filtering method [12]. Signal component of interest can be enhanced by&nbsp;using Butterworth filters in the frequency domain [13] and the correlation based signal improvement algorithm [14].</p>
194
195
<p>With the aid of this dataset, cerebral autoregulation, baroreflex function and spontaneous neurovascular coupling can be studied. The simultaneously recorded TCD, BP, NIRS and BB signals support&nbsp;elimination of systemic components from cerebral hemodynamic fluctuations. Findings&nbsp;from this dataset have been published in the paper of Mukli et colleagues [15] entitled "Two-Tiered Response of Cardiorespiratory-Cerebrovascular Network to Orthostatic Challenge". In this study, a network physiology approach was implemented using a linear and model-free estimator to characterize the effects of postural changes on the interdependent physiological processes in different frequency bands.&nbsp;</p>
196
197
<h3>Limitations</h3>
198
199
<p>Since the stand-up and sit-down maneuvers were inherently associated with perturbations generating large and&nbsp;transient motion artifacts in the physiological records, it was necessary to exclude the very early phase of the postural challenge from our analysis [15]. Consequently,&nbsp;assessing dynamic cerebral autoregulation is difficult to do reliably. The time periods after the resting-state may be too short for certain stochastic time series analysis due to a limited number of data points necessary for statistical reliability. Recovery of hemodynamics cannot be fully assessed in the last sit-down period since one minute was found to be too short to achieve a new steady-state.</p>
200
<hr>
201
202
203
204
205
206
207
  <h2 id="acknowledgements">Acknowledgements</h2>
208
  <p>&nbsp;We would like to thank all&nbsp;<em>participants</em>&nbsp;of the study. We acknowledge the support from</p>
209
210
<ul>
211
    <li>Prof Britton Chance who designed and constructed (NIM Inc., University of Pennsylvania, USA)&nbsp;the near-infrared imager&nbsp; used in the study&nbsp;</li>
212
    <li>Semmelweis University, Department of Neurology for providing the device for transcranial Doppler sonography (<span><span>DWL Multidop-T, Sipplingen, Germany</span></span>) and blood pressure measurement <span><span>(Colin BP-508, Colin Medical Technology Corporation, Komaki City, Japan)</span></span>.&nbsp;</li>
213
</ul>
214
  <hr>
215
216
217
<h2 id="conflicts-of-interest">Conflicts of Interest</h2>
218
<p><span><span><span>The authors declare no conflict of interest.</span></span></span></p>
219
<hr>
220
221
222
  <h2 id="references">References</h2>
223
  <ol>
224
  
225
    <li>Cannon WB. ORGANIZATION FOR PHYSIOLOGICAL HOMEOSTASIS. Physiol Rev. 1929;9(3):399-431.</li>
226
  
227
    <li>Ivanov PC, Nunes Amaral LA, Goldberger AL, Stanley HE. Stochastic feedback and the regulation of biological rhythms. Europhysics Letters. 1998;43(4):363-8.</li>
228
  
229
    <li>Ashkenazy Y, M. Hausdorff J, Ch. Ivanov P, Eugene Stanley H. A stochastic model of human gait dynamics. Physica A. 2002;316(1):662-70.</li>
230
  
231
    <li>Lo CC, Amaral LAN, Havlin S, Ivanov PC, Penzel T, Peter JH, et al. Dynamics of sleep-wake transitions during sleep. Europhysics Letters. 2002;57(5):625-31.</li>
232
  
233
    <li>Bashan A, Bartsch RP, Kantelhardt JW, Havlin S, Ivanov P. Network physiology reveals relations between network topology and physiological function. Nat Commun. 2012;3:702.</li>
234
  
235
    <li>Bartsch RP, Liu KKL, Bashan A, Ivanov PC. Network Physiology: How Organ Systems Dynamically Interact. PloS one. 2015;10(11):e0142143.</li>
236
  
237
    <li>Lin A, Liu KKL, Bartsch RP, Ivanov PC. Dynamic network interactions among distinct brain rhythms as a hallmark of physiologic state and function. Commun Biol. 2020;3(1):197.</li>
238
  
239
    <li>Koeppen, and Bruce A. Stanton. Berne &amp; Levy Physiology. Philadelphia, PA: Mosby/Elsevier, 2010.</li>
240
  
241
    <li>Pan J, Tompkins WJ. A real-time QRS detection algorithm. IEEE transactions on biomedical engineering. 1985(3):230-6.</li>
242
  
243
    <li>Sun J, Reisner A, Mark R, editors. A signal abnormality index for arterial blood pressure waveforms. 2006 Computers in Cardiology; 2006: IEEE.</li>
244
  
245
    <li>Racz FS, Mukli P, Nagy Z, Eke A. Increased prefrontal cortex connectivity during cognitive challenge assessed by fNIRS imaging. Biomedical Optics Express. 2017;8(8):3842-55.</li>
246
  
247
    <li>Molavi B, Dumont GA. Wavelet-based motion artifact removal for functional near-infrared spectroscopy. Physiological measurement. 2012;33(2):259-70.</li>
248
  
249
    <li>Kirilina E, Jelzow A, Heine A, Niessing M, Wabnitz H, Bruhl R, et al. The physiological origin of task-evoked systemic artefacts in functional near infrared spectroscopy. Neuroimage. 2012;61(1):70-81.</li>
250
  
251
    <li>Cui X, Bray S, Reiss AL. Functional near infrared spectroscopy (NIRS) signal improvement based on negative correlation between oxygenated and deoxygenated hemoglobin dynamics. Neuroimage. 2010;49(4):3039-46.</li>
252
  
253
    <li>Mukli P, Nagy Z, Racz FS, Portoro I, Hartmann A, Stylianou O, et al. Two-Tiered Response of Cardiorespiratory-Cerebrovascular Network to Orthostatic Challenge. Frontiers in Physiology. 2021;12(216).</li>
254
  
255
</ol>
256
257
  <hr>
258
259
260
          
261
          
262
        
263
      </div>