Switch to unified view

a b/mit-bih-arrhythmia-database-1.0.0/232.hea
1
232 2 360 650000
2
232.dat 212 200 11 1024 975 -3452 0 MLII
3
232.dat 212 200 11 1024 1066 -26934 0 V1
4
# 76 F 2777 3655 x2
5
# Aldomet, Inderal
6
# The rhythm is compatible with sick sinus syndrome.  There is underlying
7
# sinus bradycardia, first degree AV block, and frequent ectopic atrial runs
8
# at rates of 80 to 90 bpm.  There are numerous long pauses up to 6 seconds
9
# in duration.