a b/README_for_Regionalization.txt
1
Data from: “Automatic Supporting System for Regionalization of Ventricular Tachycardia Exit Site in Implantable Defibrillators”
2
3
Sanromán-Junquera, Margarita; Mora-Jiménez, Inmaculada; Almendral, Jesús; García-Alberola, Arcadio; Rojo-Álvarez, José Luis.
4
5
IDPatient: patient identifier
6
NumberOfPacingSite: pacing site number
7
Half-1: apical vs basal half
8
Half-2: septal vs lateral half
9
Half-3: superior vs inferior half
10
TypeOfTissue: scar or normal tissue: 2 ( > 1.5 mV), 1 (1.5 - 0.5 mV), 0 (< 0.5 mV).
11
X: X coordinate of the pacing site
12
Y: Y coordinate of the pacing site
13
Z: X coordinate of the pacing site
14
Vp: voltage of peak deflection
15
Vi: voltage of initial deflection
16
Vf: voltage of final deflection
17
tob:  time interval between the onset of far-field electrogram and the bipolar intrinsic deflection
18
tp:  time instant of Vp
19
ti:  time instant of Vi
20
tf: time instant of Vf
21
Far-fieldEGMWaveformWithStim:  averaged beat waveform far-field electrogram
22
BipolarEGMWaveform: averaged beat waveform bipolar electrogram.